Filters
Question type

Study Flashcards

What would happen if a hydronic system was installed without an expansion tank?

Correct Answer

verifed

verified

When water is heated, it expan...

View Answer

The vanes of the impellers used in circulating pumps in hot water heating systems are usually enclosed, and are referred to as ____________________ impellers .

Correct Answer

verifed

verified

An expansion joint is a device used to ____.


A) prevent damage between boiler sections
B) enlarge the expansion tank in the system
C) allow for expansion and contraction of the loop piping with water temperature changes
D) connect the manual vent into the system

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

On systems that use two-port zone valves, excessive pressure in the supply header may result when multiple zone valves ____________________.

Correct Answer

verifed

verified

A high-limit control on a hot water boiler is needed to ____.


A) regulate the amount of water to each section of baseboard
B) regulate the water in the supply line to the boiler
C) balance the water flow rate in the piping system
D) protect the boiler against excessive water temperatures

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

Zone control valves are controlled by ____________________.

Correct Answer

verifed

verified

Automatic air vents rely on an internal disc that swells when water is sensed.

A) True
B) False

Correct Answer

verifed

verified

Why must the expansion tank always be located higher than the boiler?

Correct Answer

verifed

verified

To permit air in the...

View Answer

The expansion tank provides a means of removing the air from the system as well as provides ____ .


A) a space for excess water from the supply source
B) water for the domestic hot water coil
C) a space for the water expansion and contraction with water temperature changes
D) All of the above.

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Discuss the outdoor reset control.

Correct Answer

verifed

verified

The outdoor reset control is the device ...

View Answer

Explain the purpose of the pressure relief valve.

Correct Answer

verifed

verified

The American Society of Mechanical Engin...

View Answer

What is the purpose of a system pressure differential bypass valve?

Correct Answer

verifed

verified

On systems that use two-port zone valves...

View Answer

The only place a bleed valve is needed is on top of the boiler.

A) True
B) False

Correct Answer

verifed

verified

Hydronic heat circulators are centrifugal pumps.

A) True
B) False

Correct Answer

verifed

verified

In a series loop, the water going through the last terminal unit will be the same temperature as the water through the first terminal unit.

A) True
B) False

Correct Answer

verifed

verified

Showing 21 - 35 of 35